• Central Line Training Model using Ultraound

    $920.00


    Exceptionally Realistic

    -         Unique design that looks, feels, and produces images similar to the human body. Different tissue layers are simulated in detail from a flexible moving skin, to elastic subcutaneous and muscle tissues, and rigid bones.

     1 phantom, 100 different patients

    -         Multiple possible challenges during central line insertion are modeled in this mannequin. Vessel angulation, branching, tortuous veins, various depth and diameters, proximity to artery, vein-under-artery, presence of clot and dissection are simulated in our model. These are in addition to the anatomical normal internal and external jugular veins and arteries.

    -         Refine your vascular expertise with the variety of vascular structures, even if you are already an expert.

    -         Expertise comes with practicing and experiencing a variety of different tasks. The variety of incorporated challenges significantly boosts the hand-eye coordination of the interventionists.

    -         External landmarks such suprasternal notch, sternum, trachea and clavicle are replicated. The density of the bony structures are the same as a real human skeleton in order to make realistic images under X-ray and CT scan

    -         Our unique nano-polymer design combines high quality imaging and realistic intervention  (see why)

    Durable and Efficient

    -         Durable: resistant to needle and catheter insertion, extreme temperature, dehydration and decomposition

    -         No replacement part is needed (Durable models should not need any replacement parts)

    -         Self-healing

    -         Double the practice area: Both sides of the neck are usable and the neck can be positioned toward the left or right sides. This will double the practice area for educational sessions.

    -         High resistance to fire and extreme temperature

    Life-like Procedure

    -         Skin motion over the soft tissue: a more natural procedure:

    American Bionic phantoms have integrated skin that is designed to simulate the skin-needle interaction as well as the skin wrinkling, and skin motion over the tissue. Skin motion over the tissue is one of the challenges faced during cannulation, especially in the thin elderly. You can decrease the skin wrinkling by adding extra blood fluid or increase the wrinkling by adding less fluid (simulated dehydaration). While adding the skin layer increases the complexity of phantom design and price of the phantom, it brings realistic needle-tissue and dilator-tissue interaction, which is a huge advantage during training.

    -         Realistic artery/vein compressibility

    -         Realistic simulation of skin-needle interaction and soft tissue-needle interaction: Different regions have different skin resistance and tensile strength to provide the trainees with a higher level of clinical exposure.

    -         Life-like reproduction of skin-dilator interaction and soft tissue-dilator interaction.

    -         Verify the needle tip by observation of fluid return from the needle or catheter.

    -         The possibility to perform the complete cannulation process; starting from needle insertion to guidewire threading, dilation, and catheter placement.

    -         No needle clogging of phantom. The needle does not break down the model.

    -         Highly scientific mannequin design and manufacturing: We go beyond molding with traditional silicon and embedded tubes. Our unique phantom manufacturing process incorporates sophisticated production of nano-polymer elements that mimic tissue elasticity, attenuation, speed of sound, tissue recoil, friction with guide-wire and catheter, tissue resistance with respect to the needle, dilator and catheter. Vessel layers are made of arrays of polymer filaments, not silicon or plastic tubes.

    -         Supports both ultrasound-guided and blind central line practices.

    -         Arterial pulse can be simulated by a hand bulb.

    -         Easy refill using the refilling port. It is possible to connect a tube to a hanging saline bag for large scale practice sessions or to maintain venous pressure. Also, it is possible to be connected to a pressure bag for arterial cannulation and pressure measurement.

    -         Easily portable: The purchase includes a container bag for easier transportation, though no specific storage is required.

    -         Accessories for easier practice are included, such as practice sheets and a repair kit (in case of accidental damage).

    -         The purchase includes our Blue and red AmericanBionic blood mimicking fluid. The fluid is concentrated for easier transportation.

    -         Our product is used to gain expertise at the desired time and location, without any risk, cost or inconvenience.

    -         Develop expertise for ultrasound/x-ray/Fluoroscopy/CT imaging.

    -         Become comfortable with ultrasound transducer maneuvering and machine settings.

    -         Returns are accepted within the first thirty days, no questions asked.

    -         Custom made models can be ordered.

    -         Manufactured in the USA.

    -         Green: Our new polymer nanofibers are earth friendly.

    -         The materials and fluid used in the model are inert with no toxicity. To further minimize any possibility of allergy the model is covered by an inert gloss of 3 micrometer thickness.

    -         Size/weight: 40 X 30 X 30 cm (depending on the custom order), 8 lbs